Elevator control panels
لوحات تحكم المصاعد

Electric elevators are one of the most important technological inventions that saved a lot of effort, and these elevators include some buttons that must be well known for the safety of the operating condition, and the requirements for elevator controls and their indicators are subject to local accessibility codes, and there are three elements required in the elevator lobby: floor designers, call buttons, Hall lanterns.

To get more information, we will show in this article about what elevator control panels are, how to install elevator control panels, and about the best organization that provides the best types of elevator control panels in Egypt.

Elevator control panels

The controls inside the elevator cabin vary greatly, based on the many types of services that the owner wishes to place on the control panel, and the floor selection buttons are also used, which serve to determine the floors at which the elevator will stop, and the highest button for the floor should be at 54 degrees above the final or lower floor, the diameters are 3/4 The displayed Heights are also ADA standards for the available design and the call buttons are used for the elevator request, as they are installed 42 inches above the finished floor and consist of an up button and a Down button that lights up dramatically to indicate that the request has already been received and there is an elevator on the way.

The Hall lanterns are also used to indicate the upcoming elevator and the direction that this will take in addition to the illuminated direction indicators, the Hall lanterns also have a sound tone to indicate the direction, and these sound signals are heard once for elevators that are going up and sound twice for elevators that are going down, in addition, the sound indicators may say “going up” or “going down” instead Of the tones, the Hall lanterns are installed at least above the finished floor as they should be visible from the vicinity of the call buttons.

Elevator control panel

Elevator control where, in addition to the control panel in the cab, the interior of the elevator cabin will contain a floor location indicator, this indicator can also be placed above the cabin control panel or centered above the elevator doors, in addition to the visual numbers representing the floor at which the cab stops, there must also be an audio signal, as it contains Newer elevators have a verbal indication of the floor and a different direction of ascent, as in the “sixth floor, descent”.

Elevator door control buttons are also used to control elevator doors, and in some modern elevator brands such as Mitsubishi AndHitachi, The lighting of the door opening and closing buttons will be provided when the button is pressed and illuminated when not holding it, and the door suspension button will also be illuminated if pressed and illuminated when the door is closed.

The door opening button is on the left side while the door closing button may be on the right side, and some elevators have this arrangement in reverse.

Most elevators have buttons to control the door under the floor buttons, but there may be some old Japanese and automatic elevators there (Such as Hitachi Toshiba Fujitec And Schindler Japan) That they are usually located above the floor buttons.

There are some types of modern elevators Kone Mitsubishi The elevators installed in America with two landing doors (front and rear) also have two door control buttons on the Control Panel, these four buttons are used, as follows where two of them are to operate the front doors while the other two are used to operate the rear doors.

Topics of interest to you:

Fingerprint device for attendance and departure

Electronic security portals

ZKTeco agent in Egypt

Types of elevator cabins

Where the types of Standard elevator cabins can be classified according to the number of entrances and their locations, they are as follows as follows:

  • An ordinary cabin.
  • Diagonal cabins.
  • Open through the cab.
  • Elevator control

There are many buttons that control elevators in general, and we will mention through the following lines about the most famous of those elevator control panels, which are as follows:

Elevator door opening button

As the door open button is used to reopen the doors when they are closed, it also works to open the door when pressed, however, pressing the door open button for a longer period of time will cause the alarm bell to ring and work to close the doors slowly, the door open button is usually identified as a do symbol, and usually also What the open door buttons are located on the left side next to the door closing button in most elevators, in addition, few elevators have their own code variants, this is the only door control button compulsorily installed in the elevator.

Elevator door suspension button

The door hang button can be used with the aim of keeping the door open for a desired period (usually three to five minutes) to load those goods, luggage, bed or stretcher, this button is especially common in freight elevators and hospital beds, the door hang button is also usually identified as extended opening, Open suspension, DH Or simply the door can be hung or the elevator cabin can be suspended.

Elevator door closing button

The door close button can be used to close the elevator immediately, as there are some types of European elevators and some types of modern elevators also may not have a door close button, instead, pressing the floor button can immediately close the door, in some other countries, there is a door close button for other services such as firefighter's Operation or independent service, but it is not operable during normal use, and the door closing buttons are usually located on the right side next to the door opening button on most elevators.

The price of the insurance card

Factors affecting the price of the insurance card:

  1. Capacity and dimensions: the larger the capacity and dimensions, the higher the price of the Access Card. The appropriate size should be selected in accordance with the expected number of passengers and the needs of the building.
  2. Technology and specifications: the technology and specifications of the ascension card vary depending on the manufacturer and model. An insurance card with advanced technologies and high specifications has a higher price.
  3. Usage and additional costs: the price of the utility card is affected by the type of building and its use. Commercial buildings, hospitals and hotels may need special specifications such as security and high speed, which affects costs.

In the latter

We have talked in this article about everything related to elevator control panels, the prices of insurance cards in Egypt, their most important uses, specifications and the most important advantages, and what is the best company that provides elevator control panels in Egypt Therefore, you can order modern technologies and devices with high technologies and quality through us at “zkteco " for security services, and any special request can also be provided according to your desire, so all you have to do is contact us at our numbers or by leaving a comment so that our special team will communicate with you immediately with a continuous service 24 hours throughout the day, in addition to Provide after-sales service.